- Low-tension electric wire for Automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
- Especially used circuits requiring heat resistance
Part Number |
Conductor Construction | Insulation Wall Thickness Nom. |
Cable | Max. Conductor Resistance at 200C |
Current Carrying Capacity |
Standard Length* |
||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom. |
Overall Diameter Max. |
Weight Approx |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
86806XX* | 0.5 | 16 | 0.21 | 1.10 | 0.6 | 2.6 | 9 | 39.0 | 8 | 500 |
86808XX | 0.75 | 24 | 0.21 | 1.30 | 0.6 | 2.8 | 11 | 26.0 | 10 | 500 |
86810XX | 1 | 32 | 0.21 | 1.50 | 0.6 | 3 | 13 | 19.5 | 12 | 500 |
86813XX | 1.5 | 30 | 0.26 | 1.80 | 0.7 | 3.5 | 19 | 13.3 | 16 | 500 |
86816XX | 2.5 | 50 | 0.26 | 2.20 | 0.8 | 4.2 | 31 | 7.98 | 22 | 500 |
86819XX | 4 | 56 | 0.31 | 2.80 | 0.8 | 4.8 | 47 | 4.95 | 30 | 500 |
86827XX | 10 | 80 | 0.41 | 4.50 | 1 | 7.6 | 115 | 1.91 | 52 | 500 |
86828XX | 16 | 126 | 0.41 | 6.30 | 1 | 8.8 | 168 | 1.21 | 76 | 500 |
86830XX | 25 | 196 | 0.41 | 7.680 | 1.1 | 10.8 | 203 | 0.780 | 96 | 500 |
86832XX | 35 | 276 | 0.41 | 9.00 | 1.2 | 12.8 | 357 | 0.554 | 120 | 500 |
86834XX | 50 | 396 | 0.41 | 10.50 | 1.4 | 14.5 | 508 | 0.386 | 155 | 500 |
86837XX | 70 | 360 | 0.51 | 12.50 | 1.4 | 16.6 | 750 | 0.272 | 195 | 500 |
86838XX | 95 | 475 | 0.51 | 14.80 | 1.6 | 19 | 1000 | 0.206 | 240 | 500 |
86841XX | 120 | 608 | 0.51 | 16.50 | 1.6 | 21 | 1300 | 0.161 | 280 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.