More Category
Aerospace Cables
Airport Lighting Cables
Appliance Wires & Cables
Automotive Cables
Battery Cables
Building Wires
Composite/Hybrid Cables
Control & Switchboard Cables
Diamond Colourisation
Fibre Optic Cables & Accessories
Fire Resistant Cables
Flexible Cables
Heat Shrinkable Products
High Temperature Cables PW 125, Sietherm 125, Sietherm 155 & Fluoro 200
Instrumentation Cables
Irrigation Communication Cables
Jelly Filled Telecom Cables
Linear Heat Detection Cable
Mining Cables
Nuclear Cables
Offshore, Marine, Shipboard & Boat Cables
Oil & Gas, Petrochemical Cables
Power Cables
Power Cords
PW 125 Wires for High rise building & Panel Wiring
Railway Quad & Signalling Cables
Rolling Stock Cables For Electric & Diesel Train
Rubber Cables
Silicone Cables
Soft Drawn Bare Copper Conductor
Solar Cables
TEFLON, ETFE, PTFE, FEP, PFA, PEEK, PVDF & KAPTON Cables
Telecommunication Cables
Tri-rated Cables
Welding Cables
Wind Energy Cables
Wiring Harness
Cables by Standard
Nuclear Cables
Siechem ATC Conductor, EBXL-XLPE Insulated & CSPE sheathed 600 V Rated Instrumentation cable
Instrumentation Cable is a 600 V, individual shielded pairs or triads with overall shield, thermoset, Class IE rated construction specifically designed for application in nuclear generating stations and where flame retardancy is critical
Designed for use on circuits where overall shielding is required to protect from external electrostatic interference, but not shielding between conductors.
Can be installed in trays, conduit, ducts, or in direct burial applications
Conductor : Annealed Tinned copper as per ASTM B33
Insulation : Flame-retardant, heat-moisture and radiation-resistant, themoset cross-Linked Polyethylene (EBXL-XLPE 120oC)
Outer sheath : Heavy-duty chlorosulphonated polyethylene (CSPE) – Black.
Rated Voltage : 600 V
Temperature Rating :120°C
Specification :
(i) Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974
(ii) ICEA S-73-532
Rated at 90°C wet or dry
Fully traceable
Qualified for 40-year service life
Radiation resistant (up to 200 megarads)
Maximum flame-retardancy
Long-term moisture and radiation stability
Long-term thermal endurance and superior electrical
Excellent mechanical cut through properties
Free stripping for ease of termination
Meets cold bend test at -40oC
Part Number
No.of
Cond.
Cond.
Size
Cond.
Strand
Insulation Thickness
Jacket
Thickness
Cable Diameter
Copper Index (approx.)
Cable Weight (approx.)
mm
mm
mm
kg/km
kg/km
95581XX
2/C
18
7/0.386
0.64
1.14
7.75
15
76
95581XX
3/C
18
7/0.386
0.64
1.14
8.0
23
85
95581XX
4/C
18
7/0.386
0.64
1.14
8.64
30
106
95581XX
5/C
18
7/0.386
0.64
1.14
9.40
38
118
95581XX
7/C
18
7/0.386
0.64
1.14
10.16
53
146
95581XX
9/C
18
7/0.386
0.64
1.14
11.68
68
182
95581XX
12/C
18
7/0.386
0.64
1.14
13.08
76
229
95581XX
19/C
18
7/0.386
0.64
1.52
16.0
143
359
95581XX
25/C
18
7/0.386
0.64
1.52
18.54
189
458
95581XX
30/C
18
7/0.386
0.64
1.52
19.43
225
522
95581XX
37/C
18
7/0.386
0.64
1.52
21.05
280
632
95580XX
2/C
16
7/0.488
0.64
1.14
8.13
24
83
95580XX
3/C
16
7/0.488
0.64
1.14
8.51
36
103
95580XX
4/C
16
7/0.488
0.64
1.14
9.27
48
127
95580XX
5/C
16
7/0.488
0.64
1.14
10.03
60
147
95580XX
7/C
16
7/0.488
0.64
1.14
10.92
84
190
95580XX
9/C
16
7/0.488
0.64
1.14
12.7
108
238
95580XX
12/C
16
7/0.488
0.64
1.52
15.0
145
329
95580XX
19/C
16
7/0.488
0.64
1.52
17.27
229
473
95580XX
25/C
16
7/0.488
0.64
1.52
20.07
302
604
95580XX
30/C
16
7/0.488
0.64
1.52
22.35
363
762
95580XX
37/C
16
7/0.488
0.64
2.03
24.0
447
915