MOD 02 526

NES 526 – TABLE C11 : Multicore Cables, Cores Collectively Screened

  • Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines.
  • Used in fuel and lubrication oils, hydraulic fluids and water surfaces.
  • Ship systems & equipments and weapon systems & equipments.

  • Conductor : Circular Electroplated, annealed tinned copper wire (Class 2) complying with BS : 6360
  • Insulation : Dual extrusion (Type GP 5 / LFH)
  • Laying up
  • Binder Tape : Polyethylene Teraphthalate
  • Braiding : Annealed Tinned Copper braid (95% Coverage)
  • Outer Sheath : Limited Fire Hazard complying with NES 518 Material

  • Temperature Range                       : – 350C to +1050C
  • Rated Voltage (U°/U)                     : 440 V
  • Test Voltage                                     : 1.5/3 kV
  • Bending Radius(Min)                      : 6 x Cable Diameter

  • Limited Fire Hazard
  • Halogen free

Part Number Number of Cores and mm2
Per Conductor
Outer Diameter in
mm approx.
Copper Index
Kg/Km
Total Weight
Kg/Km approx.
521-8463 2C x 4.0 13.4 70 305
521-8464 2C x 16 20.5 279 784
531-0227 3C x 10 18.7 261 662
531-0228 3C x 16 21.9 418 954
531-0229 3C x 25 26.7 653 1403
531-0230 3C x 35 28.8 914 1761
531-0231 3C x 50 33.3 1306 2432
521-8530 4C x 1.0 15.4 35 348
521-8466 4C x 2.5 13 87 304
521-8531 4C x 6.0 27.2 209 1022
531-7042 19C x 0.5 18.3 83 484
531-7043 27C x 0.5 21.3 118 706
531-7044 37C x 0.5 24.5 161 880